Common Heating Problems We Repair

  • The heater will not start. Systems that sat idle since spring often fail on the first cold morning. Igniters, flame sensors and control boards are the usual suspects.
  • Blowing cold air. A furnace that runs without heating can have an ignition problem, a limit switch issue or, on heat pumps, a failed reversing valve.
  • Short cycling. The system starts and stops without warming the house. Often airflow or a safety switch doing its job.
  • Burning smell or strange noises. Shut the system off and call. Dust burn-off on first start is normal for a few minutes; anything beyond that deserves a look.

The Same Process As Our AC Work

The AC repair page lays out the readings we take. Heating calls get the same sequence on the furnace side, and a spring tune-up catches most of the parts that fail in winter too.

Same rules as the AC calls: test it, tell you what's wrong, price before we start.

Most Arlington homes keep the furnace and the AC in the same cabinet. One call covers both sides.

Heat Pump Or Gas Furnace?

The two systems fail in different ways. Heat pump repair covers defrost, reversing valves and backup heat. Furnace repair walks through the gas ignition sequence and where it usually stops. For the whole system at once, see HVAC repair.

Heating Questions From Arlington Winters

Why is my furnace running but blowing cold air?

The blower is moving air but the burners are not lighting or are shutting off early. Common causes: a dirty flame sensor, an igniter that failed, a limit switch tripping on low airflow, or a thermostat set to Fan On. On a heat pump, cold air in heating mode can be a normal defrost cycle or a failed reversing valve.

Why won't my heater start on the first cold morning?

Systems that sat idle since March fail on the first cold snap more than any other day of the year. Igniters, flame sensors and control boards are the usual reasons. Check the thermostat is set to Heat and the filter is not packed, then call if it still will not fire.

What does the blinking light on the furnace mean?

It is an error code. The board blinks a pattern and the legend is printed inside the furnace door. Count the blinks, note the pattern, and tell us when you call. It points us at the failed part before we arrive.

Is a burning smell normal when the heat comes on?

For the first few minutes of the season, yes. That is dust burning off the heat exchanger. A smell that lasts, smells electrical, or comes with a strange noise is not normal. Shut the system off and call.

Do heat pumps keep up in Arlington winters?

Yes. North Texas winters are mild enough that a heat pump handles most of the season on its own, with electric backup strips for the handful of hard freezes. Steam or frost off the outdoor unit during a defrost cycle is normal.

Can a gas furnace make my family sick?

A cracked heat exchanger or a blocked vent can put carbon monoxide into the house. Every home with gas heat should have a working CO detector near the bedrooms. Headaches, nausea or a detector alarm mean shut the furnace off, get outside, and call.