AC Leaking Water? Drain Line Repair in Arlington

Home » AC Repair » AC Leaking Water

An air conditioner pulls a lot of water out of humid Texas air. On a muggy Arlington day a central system can drain gallons through the condensate line. When that water has nowhere to go, it ends up on your floor, in the closet, or through a ceiling stain under an attic unit.

Indoor air handler and ductwork where condensate drains from the coil

Stop The Damage First

  • Turn the system off at the thermostat. Less cooling means less water.
  • Find the indoor unit: a hall closet, the garage, or the attic. Look for a pan under it with standing water.
  • Soak up what you can and put towels or a bucket under the drip. On attic units, check the ceiling below for a darkening spot.

Why AC Units Leak Water

  • A clogged condensate drain. Algae and sludge grow in the line, especially in summer humidity. This is the most common cause by far.
  • A full secondary pan. Attic units sit over a backup pan. If it fills, the primary drain has already failed.
  • A rusted or cracked drain pan. Older coils often have metal pans that rust through.
  • A melting frozen coil. If the system froze, the thaw dumps more water than the drain can handle. See frozen AC.
  • A disconnected drain line or failed condensate pump. Common after other work in the attic or closet.

Many systems have a float switch in the drain line or pan that shuts the AC off when water backs up. If your system stopped cooling and you find water in the pan, that switch did its job. The drain still needs to be cleared. If the unit will not restart at all, see AC won't turn on.

What We Do

We clear the line from both ends, flush it, check that the pan and float switch work, and look at why it clogged. A line with no trap or poor slope will keep clogging. A tune-up includes drain flow every spring, which is the easiest way to keep this from happening in July. See AC tune-ups.

Related Repairs

AC Leaking Water: Common Questions

How fast do I need to deal with an AC water leak?

Right away. A leak from an attic unit can soak drywall and insulation within hours, and a slow leak in a closet can rot the floor and grow mold over a few weeks. Turn the system off and catch the water until the drain is cleared.

Does homeowners insurance cover AC water damage?

It depends on the policy and on how the damage happened. Many policies treat sudden water damage differently from damage caused by long-term neglect or a slow leak. Take photos and call your insurance company before repairs if the ceiling or floor is damaged.

Why did my AC shut off when the drain pan filled with water?

That is a float switch, a safety device that cuts power to the cooling when water backs up. It protects your ceiling. Once the drain is cleared and the water is gone, the switch resets and the system can run again.

How do I clear my AC drain line myself?

Find the outdoor end of the drain line, usually a PVC pipe near the outdoor unit or foundation, and pull the clog out with a wet vac. Pouring a cup of white vinegar into the access tee at the indoor unit every few months helps slow algae growth.

Why is water dripping from a ceiling vent?

Water at a supply vent is usually condensation. Cold air in a duct that runs through a hot, humid attic sweats when the duct insulation is damaged or the vent boot is not sealed. It can also mean the attic unit's pan is overflowing above that spot.