An air conditioner that runs but does not cool is the most common call we get in Arlington from May through September. Sometimes it is a five-minute fix. Sometimes it is the start of a bigger failure. Here is how to tell which, and what you can safely check yourself.

Check These First
- Thermostat: set to Cool, fan on Auto, and the set point below room temperature. A fan left on On blows air all day whether the system is cooling or not.
- Air filter: pull it and hold it to the light. If you cannot see through it, replace it. A packed filter starves the coil of air.
- Outdoor unit: is the fan on top spinning? Is the unit running at all? Check the breaker in the panel and the disconnect box on the wall by the unit.
- Vents and returns: make sure furniture or rugs are not blocking the return grille. Closing vents in unused rooms does not help and can freeze the coil.
What Usually Causes It
When the basics check out, the cause is almost always one of these:
- A weak or dead capacitor. The outdoor fan or compressor cannot start. Texas heat wears these out faster than anything else. More on capacitor failure.
- A dirty condenser coil. Cottonwood fluff, grass clippings and dust pack the fins and the unit cannot shed heat on a 100 degree afternoon.
- Low refrigerant from a leak. Cooling fades over weeks or months, the lines may sweat or ice. See refrigerant leak repair.
- A frozen evaporator coil. Airflow drops, ice builds, and eventually no air comes out at all. See frozen AC.
- Blower or duct problems. Weak airflow from every vent points to the blower motor, a collapsed duct, or a disconnected duct in the attic.
When The House Just Cannot Keep Up
On the hottest Arlington afternoons, a healthy system may run nonstop and hold the house a few degrees above the set point. That alone is not a failure. What matters is the temperature drop across the indoor coil. If supply air is not roughly 15 to 20 degrees colder than return air, something is wrong. If it is, and the house still climbs, the cause is usually attic duct leaks, missing insulation, or a system that was never sized for the house.
Related Repairs
AC Not Cooling: Common Questions
Why is the air from my vents cool but not cold?
Air that feels cool but not cold usually means the system is moving heat, just not enough of it. The usual causes are a dirty outdoor coil, low refrigerant, or a weak compressor. A temperature reading at a supply vent and the return grille tells us how far off it is.
Why is one room hotter than the rest of the house?
Uneven rooms are almost always airflow, not the air conditioner itself. A crushed or disconnected duct in the attic, a room with no return path when the door is closed, or a west-facing room with big windows will run hotter than the rest.
Can a dirty outdoor unit stop my AC from cooling?
Yes. The outdoor coil is where the heat from inside your house gets released. When the fins are packed with dirt and cottonwood, pressures climb, the compressor works harder, and cooling drops off on the hottest days, exactly when you need it.
Why does my AC cool fine at night but not in the afternoon?
At night the load is lower, so a system with a marginal problem can still keep up. When the afternoon sun hits the roof and walls, the same problem shows. A weak capacitor, low charge, or dirty coil are the usual reasons a system loses ground after lunch.
Will setting the thermostat lower cool the house faster?
No. A central air conditioner cools at one speed no matter where the set point is. Dropping it to 60 just makes the system run longer and can freeze the coil. Set the temperature you want and let it run.
AC Not Cooling In Arlington?
The phone is answered 24 hours a day. Call and describe what you are seeing.