Refrigerant is not fuel. A sealed air conditioning system uses the same charge for its whole life. If the charge is low, it leaked out somewhere, and adding more without finding where only buys time.

Signs Of A Refrigerant Leak
- Cooling that gets a little weaker every summer, or that was fixed by a recharge and faded again.
- Ice on the outdoor copper line or the indoor coil. See frozen AC.
- Long run times and higher electric bills with no change in how you use the system.
- A hissing or bubbling sound near the indoor coil or the outdoor unit.
- Oily spots on copper joints or at the service valves.
How We Find Leaks
Gauges tell us the charge is low. Finding the leak is the real work. We use an electronic leak detector along the coils, joints and valves, bubble solution on suspect spots, and when needed a nitrogen pressure test that shows whether the system holds pressure at all. Common leak points are the indoor evaporator coil, the service valve cores, and copper rubbing against something in the attic or wall.
Repair, Recharge, Or Replace
A leaking valve core or a brazed joint is a straightforward repair. A leaking evaporator coil is a bigger decision on an older system, because the coil, the refrigerant and the labor add up. We give you both numbers and the age of the system so you can weigh it. See repair versus replacement.
If Your System Uses R-22
Systems installed before about 2010 often run on R-22, which is no longer produced in the United States. What is left is reclaimed supply, and it is expensive. A large R-22 leak on an older system is usually the point where replacement makes more sense than a recharge. Refrigerant handling is regulated under the EPA Section 608 rules, and newer systems use different refrigerants than units from the last decade.
Related Repairs
Refrigerant Leak Repair: Common Questions
Does refrigerant need to be refilled every year?
No. A sealed system that is working correctly never needs more refrigerant. If yours needs a recharge every year, it has a leak, and each recharge costs money that could go toward fixing the leak or the system.
What if my AC system uses R-22?
R-22 is no longer manufactured in the United States, so it is only available from reclaimed stock and it costs more each year. Small leaks can still be repaired. A large leak on an R-22 system is usually the point to compare replacement.
What does AC stop-leak sealant do?
Sealant products are meant to plug very small leaks from the inside. They can also coat or clog valves, metering devices and recovery equipment. We find and repair the leak instead of adding sealant.
Is it worth fixing a refrigerant leak on an older AC?
It depends on where the leak is and how old the system is. A valve core or a single joint is worth fixing on almost any system. A leaking coil on a 15 year old R-22 unit usually is not. You get both prices so you can decide.
Refrigerant Leak Repair In Arlington?