Heat Pump Repair in Arlington, TX
A heat pump is an air conditioner that can run backward. In summer it moves heat out of your house. In winter a reversing valve flips the flow and it pulls heat in from outdoor air, even on a cold Arlington morning. Because it does both jobs, it runs more hours a year than a straight AC.

What Is Normal
- Steam from the outdoor unit in winter. That is a defrost cycle melting frost off the coil. It can last several minutes and the fan stops during it.
- A light coat of frost on cold, damp mornings that clears on its own.
- Air that feels warm, not hot. Heat pump air comes out cooler than furnace air. It still heats the house, it just does it more gradually.
- Long run times when it is near freezing outside, with backup heat strips helping on the coldest nights.
What Is Not
- Thick ice that covers the coil and never clears.
- Cold air from the vents for a long time in heat mode.
- The outdoor unit not running while the indoor fan blows.
- A big jump in the electric bill, which can mean the backup strips are doing all the heating.
- Loud grinding, banging or a loud whoosh that does not happen at the end of a defrost cycle.
Common Heat Pump Repairs
Defrost controls and sensors that fail and let ice build. Reversing valves that stick in cooling. Low refrigerant from a leak, which hurts heating even more than cooling. Outdoor fan motors and capacitors, the same parts that fail on air conditioners. Backup heat strips and their sequencers. We test both modes, because a heat pump with a heating problem usually has a cooling problem coming. For gas heat, see furnace repair.
Related Repairs
Heat Pump Repair: Common Questions
Why does my heat pump blow cool air in heat mode?
A short burst of cool air during a defrost cycle is normal. Cool air for a long stretch is not. A reversing valve stuck in cooling, low refrigerant, a failed outdoor fan, or a thermostat set up for the wrong system type are the usual causes.
Is it normal for my heat pump to have ice on it?
Light frost that melts during a defrost cycle is normal on cold, damp mornings. A solid block of ice that stays for hours means the defrost system is not working or the unit is low on refrigerant. Shut it off and call.
How do I reset my heat pump?
Turn the system off at the thermostat, switch off the breakers for the outdoor and indoor units for about five minutes, then turn them back on. If it fails again right away, something has tripped for a reason and needs to be tested.
Why does my heat pump run all the time in winter?
When it is near freezing outside, a heat pump runs long cycles to keep up, and that is normal. If it runs constantly on a mild day and the house is still cold, it may be low on refrigerant or the reversing valve may not be shifting fully.
Heat Pump Repair In Arlington?
The phone is answered 24 hours a day. Call and describe what you are seeing.