Serving Arlington, Texas and surrounding neighborhoods
24 Hour Emergency AC & Heating Repair, 7 Days a Week

Furnace Repair in Arlington, TX

Home » Heating Repair » Furnace Repair

A gas furnace lights in a set order every time it runs. When it fails, where it stops in that order tells you which part quit. Many Arlington homes have the furnace in the attic or a hall closet, often in the same cabinet as the AC coil.

Gas furnace with ductwork connected inside a home

The Startup Sequence

  • Inducer motor starts and pulls air through the heat exchanger and out the vent.
  • Pressure switch confirms the vent is clear.
  • Igniter glows or sparks.
  • Gas valve opens and the burners light.
  • Flame sensor confirms the flame within a few seconds.
  • Blower starts and pushes heat to the vents.

Where It Usually Fails

  • Lights, then shuts off in a few seconds: a dirty flame sensor. Very common after a summer of sitting idle.
  • Inducer runs, nothing lights: a pressure switch, a blocked vent, or a cracked hose to the switch.
  • Clicks or glows, no flame: a worn igniter or a gas valve that will not open.
  • Burners run, blower never comes on: a blower motor or capacitor, and the limit switch will shut the burners off to protect the furnace.
  • Runs in short bursts all day: a limit switch tripping on low airflow, usually a packed filter or blocked returns.

Safety

Combustion gases are supposed to leave through the vent pipe. A heat exchanger crack or a vent that is disconnected, rusted through or blocked by a bird nest lets them back into the living space. Put a carbon monoxide alarm on every floor where people sleep and test it each fall. If a detector sounds, get everyone outside, then call. The blinking error code on the control board helps us narrow the cause before we arrive. For heat pumps, see heat pump repair.

Related Repairs

Furnace Repair: Common Questions

Why does my furnace start and then shut off after a few seconds?

The burners light but the flame sensor does not confirm the flame, so the gas valve closes for safety. A dirty or corroded flame sensor is the usual cause, and it is common on the first cold days after the furnace has sat all summer.

Why is my furnace clicking but not lighting?

Repeated clicking with no flame usually points to the ignition system: a worn hot surface igniter, a spark igniter that is not firing, or a gas valve that is not opening. The control board will often show a blink code for it.

Why is my furnace inducer motor so loud?

The inducer is the small fan that starts first. A loud whine, rattle or grinding usually means worn bearings or a loose wheel. It needs attention, because the furnace will not light if the inducer fails.

Can I clean the furnace flame sensor myself?

It is a common homeowner fix, but it means removing panels, working near the gas valve and handling a fragile rod. If the furnace short cycles again after cleaning, the sensor, its wiring, or the ground connection needs to be checked.

Furnace Repair In Arlington?

The phone is answered 24 hours a day. Call and describe what you are seeing.

Call (682) 206-0032
Call (682) 206-0032